Trademark STARXH Origin China HS Code 90184990
Product Description
Warning·This is for dentists and dental hygienists use only.·Do not use on the following patients.
- Does not use a powder case cover if it has cracks or deep scratches in it. Such cover might break the applied air pressure,and fragments would fly.
- Do not hit or impact the powder case cover.
- Do not expose the powder case cover to organic solvents, etc. because it may break.
- Powder case cover is a consumption article. It will deteriorate by ultraviolet rays, or by other environment factors. Replace the powder case cover per 6 months.
- Take the powder case cover and rubber packing once a week, and clean the clung power. When doing this, check the powder case cover whether it has no cracks or deep scratches or not.
Caution
- Do not jet directly onto the oral soft tissues or subgingvia.
- Use clean and dry air all the time. Moist air could cause the powder to solidify and clog the powder passage.
- Care should be exercised to prevent the scattered powder from entering the patient’s other mucus membranes than oral, such as eyes and nose.
- Use our powder only. In case a trouble takes place with use of other powders, we shall not be held liable to the incident and consequences.
- Fill one pack of powder in the powder case for each patient. In case some amount of powder is left in the powder caseunused, discard it.
- Does not use the powder remained in the pack unused for an extended period of time, to avoid clogging the device by the moistened powder.
- When air prophy unit is disconnected from the coupling or from the handpiece hose, wipe water from its connecting end and from the hose. Moist powder could cause the powder passage to clog.
- To store after using, remove powder from the powder case and clean its interior.
- Remove oil, chemicals and other harmful materials from the plastic powder case cover as soon as they are found. Such may cause the cover to break in time.
Caution
CautionUse the nozzle wrench to securely tighten the nozzle nut.Sterilization
·powder case and nozzle·powder case into the body and the powder case cap·powder case cap into the O-ring, thin gasket and serrated coverring.
Caution·skip dry cycle if the chamber temperature could exceed 135ºC.·place the pouch in the central or top tray, as the local temperature at the chamber bottom could exceed the set temperature.·do not sterillize with other instruments that are not completely cleaned from the chemicals. Chemical vapors could set on the air prophy unit components and cause them to discolor or malfunction.Trouble shootingTroubleProbable causeRemedyNo air or powder exits from nozzle
- The nozzle is clogged.
Remove the nozzle when no powder in the powder case. Clean the nozzle and the powder case with the cleaning file. At last puff it by 3-way syringe.
- Powder case is clogged.
Insert the cleaning wire into the hole in the center of the nozzle joint section until it stops in the hole. If this does not solve the problem, clean the powder case body in the boiling water for 10 mins.Air and powder exit from the nozzle, but not in sufficient power.
- Power that has been left unused was used.
Change with new power
- Water invaded into the drive air passage.
Change the O-ring at the coupling end of the powder case.Check the quality of the drive air. Drain the air filter and air compressor.
- Air passage is partially blocked by the powder solidified by water.
Remove the nozzle. Clean the nozzle, powder case with the supplied wire.Water leaks from the nozzle joint at the powder caseO-ring is damaged.Change O-rings.Nozzle hardly swivels.Cleaning powder accumulated in the O-ring groove, making the nozzle swivel extremely resistive.Remove the O-rings. Brush the powder off the O-ring grooves and joint.Clean the O-rings. Put them back on the joint.
Basic Info.
Trademark STARXH Origin China HS Code 90184990
Product Description
Customer Question & Answer Ask something for more details (0)
Warning·This is for dentists and dental hygienists use only.·Do not use on the following patients.
- Does not use a powder case cover if it has cracks or deep scratches in it. Such cover might break the applied air pressure,and fragments would fly.
- Do not hit or impact the powder case cover.
- Do not expose the powder case cover to organic solvents, etc. because it may break.
- Powder case cover is a consumption article. It will deteriorate by ultraviolet rays, or by other environment factors. Replace the powder case cover per 6 months.
- Take the powder case cover and rubber packing once a week, and clean the clung power. When doing this, check the powder case cover whether it has no cracks or deep scratches or not.
Caution
- Do not jet directly onto the oral soft tissues or subgingvia.
- Use clean and dry air all the time. Moist air could cause the powder to solidify and clog the powder passage.
- Care should be exercised to prevent the scattered powder from entering the patient’s other mucus membranes than oral, such as eyes and nose.
- Use our powder only. In case a trouble takes place with use of other powders, we shall not be held liable to the incident and consequences.
- Fill one pack of powder in the powder case for each patient. In case some amount of powder is left in the powder caseunused, discard it.
- Does not use the powder remained in the pack unused for an extended period of time, to avoid clogging the device by the moistened powder.
- When air prophy unit is disconnected from the coupling or from the handpiece hose, wipe water from its connecting end and from the hose. Moist powder could cause the powder passage to clog.
- To store after using, remove powder from the powder case and clean its interior.
- Remove oil, chemicals and other harmful materials from the plastic powder case cover as soon as they are found. Such may cause the cover to break in time.
Caution
CautionUse the nozzle wrench to securely tighten the nozzle nut.Sterilization
·powder case and nozzle·powder case into the body and the powder case cap·powder case cap into the O-ring, thin gasket and serrated coverring.
Caution·skip dry cycle if the chamber temperature could exceed 135ºC.·place the pouch in the central or top tray, as the local temperature at the chamber bottom could exceed the set temperature.·do not sterillize with other instruments that are not completely cleaned from the chemicals. Chemical vapors could set on the air prophy unit components and cause them to discolor or malfunction.Trouble shootingTroubleProbable causeRemedyNo air or powder exits from nozzle
- The nozzle is clogged.
Remove the nozzle when no powder in the powder case. Clean the nozzle and the powder case with the cleaning file. At last puff it by 3-way syringe.
- Powder case is clogged.
Insert the cleaning wire into the hole in the center of the nozzle joint section until it stops in the hole. If this does not solve the problem, clean the powder case body in the boiling water for 10 mins.Air and powder exit from the nozzle, but not in sufficient power.
- Power that has been left unused was used.
Change with new power
- Water invaded into the drive air passage.
Change the O-ring at the coupling end of the powder case.Check the quality of the drive air. Drain the air filter and air compressor.
- Air passage is partially blocked by the powder solidified by water.
Remove the nozzle. Clean the nozzle, powder case with the supplied wire.Water leaks from the nozzle joint at the powder caseO-ring is damaged.Change O-rings.Nozzle hardly swivels.Cleaning powder accumulated in the O-ring groove, making the nozzle swivel extremely resistive.Remove the O-rings. Brush the powder off the O-ring grooves and joint.Clean the O-rings. Put them back on the joint.